News


IAI Overhang Load Length Info

rnOverhang Load Length Informationrnnnrn

rnPosted: 30 Dec 2009 04:37 PM PSTnnrn

nnThe overhang load length provides a reference for an appropriate offset of the load from the slider at which the actuator can operate smoothly without generating undesirable vibration.nnrnTake note that if the overhang load length is exceeded, vibration may increase the positioning time, generate longer overshooting, lower the positioning repeatability, etc.nnrnVibration can also cause the guide to get pinched or receive uneven loads and eventually fail prematurely. Accordingly, be sure to observe the allowable overhang load length. (The load coefficient will change.)nnrnBased on our experience, the overhang load length should not exceed approx. 5 based on the expression “L / l,” where L represents the overhang load length and l represents the slider length. If “L / l > 5,” use a double-guide specification or take other appropriate measures to ensure a sufficient span.nnrnnn(Supplemental information)nnrnWith a measuring system equipped with a camera, the overhang load length may take a value of approx. 3 to 4. On the other hand, you can slightly increase the value of “L/ l” in applications where you only want your actuator to operate as intended.nnrnnnoverhang-load-lengthnnrnnnTIPS-090150 – Issue date: 12/28/09nnrnnnTo download the full TIPS-090150 PDF, please click here.

Contact

317-862-9580

Location

Blettner Engineering Co., Inc.
8919 Southeastern Ave.
Indianapolis, IN 46239

Questions about assembly or automation solutions? Request Info